Skip to content

tied-biphasic

Module: biphasic

Category: surfaceinteraction

Type string: "tied-biphasic"

Parameters

Name Description Default Units
laugon Enforcement method 0 []
tolerance tolerance 0.1 []
gaptol gaptol -1 []
ptol ptol -1 []
penalty penalty 1 []
auto_penalty auto_penalty false []
update_penalty update_penalty false []
two_pass two_pass false []
knmult knmult 1 []
search_tol search_tol 0.01 []
pressure_penalty pressure_penalty 1 []
symmetric_stiffness symmetric_stiffness true []
search_radius search_radius 1 []
minaug minaug 0 []
maxaug maxaug 10 []

Description

A tied biphasic interface is similar to the tied interface. It may be used for tying any combination of solid, biphasic, and rigid materials. It enforces continuity of the fluid pressure across the interface when both materials are biphasic.

Please see tied-elastic for a more detailed explanation of the parameters.