fluid RC¶
Module: fluid
Category: bc
Type string: "fluid RC"
Parameters¶
| Name | Description | Default | Range | Units |
|---|---|---|---|---|
R |
R | 0 | \(\in \mathbb{R}\) | F.t/L^5 |
initial_pressure |
initial_pressure | 0 | \(\in \mathbb{R}\) | P |
capacitance |
capacitance | 0 | \(\in \mathbb{R}\) | L^5/F |
Bernoulli |
Bernoulli | false | \(\{0, 1\}\) |
Description¶
This boundary condition models a fluid surface that has an RC-equivalent circuit for outflow conditions.