fluid RC¶
Module: fluid
Category: bc
Type string: "fluid RC"
Parameters¶
| Name | Description | Default | Units |
|---|---|---|---|
R |
R | 0 | [F.t/L^5] |
initial_pressure |
initial_pressure | 0 | [P] |
capacitance |
capacitance | 0 | [L^5/F] |
Bernoulli |
Bernoulli | false | [] |
Description¶
This boundary condition models a fluid surface that has an RC-equivalent circuit for outflow conditions.