Skip to content

fluid RC

Module: fluid

Category: bc

Type string: "fluid RC"

Parameters

Name Description Default Units
R R 0 [F.t/L^5]
initial_pressure initial_pressure 0 [P]
capacitance capacitance 0 [L^5/F]
Bernoulli Bernoulli false []

Description

This boundary condition models a fluid surface that has an RC-equivalent circuit for outflow conditions.